CyberHandler 2 offers a solution "turnkey" for the cooling of data center

Far more than just a product, the CyberHandler 2 is a complete solution offering you not only a wide range of cooling capacities from 30 to 520 kW, but also a full range of services such as Life Cycle Cost Calculation, Reverse Osmosis water treatment, Commissioning, Maintenance and Warranty. With a high efficient indirect evaporative Free Cooling design and state-of-the-art components the CyberHandler 2 minimizes the running costs and achieves pPUE values down to 1.02 depending on application and location.

Technology and Infrastructure

  • Indirect Free Cooling: No contamination from outside air
  • Unbeatable efficiency levels with pPUE values between 1.02 - 1.10 depending on application and location
  • Year-round operation with evaporative cooling
  • Outdoor installation — Saves space in the data center
  • Reverse osmosis (Hygienic Safety, Durable)
  • Removes unwanted substances: 99 % of water impurities, 100 % of Legionella

CyberHandler 2 Select

  • Calculation of return on investment
  • Simulation of individual product requirements in the CyberHandler 2 Select and optimization of operating conditions

Service

  • Simplified installation
    • Problem-free routing of power cables, water pipes and other piping
  • Optimized maintenance conditions
    • Service engineers do not have to enter server rooms
    • Fast, low-cost maintenance
  • Low total cost of ownership (TCO)
    • Simplified capital expenditure (CAPEX), operating expenditure (OPEX), and repair and infrastructure costs
    • Reduced electrical infrastructure enables CAPEX savings of 6-8 %
 

Operating Modes

The special construction with its extremely efficient combination of Free Cooling and evaporative cooling reduces energy costs. The system has been optimized to such an extent that in most regions, 100% mechanical cooling is no longer necessary. pPUE values as low as 1.02 can be achieved. Dry Mode: At low outside temperatures, hot air from the data center is cooled down by the cold outside air via the plate heat exchanger. Wet Mode: When the outside temperature is moderate, the outside air is precooled by the adiabatic system before passing through the heat exchanger, where it cools down the air from data center. Top-Up Mode: At very high outside temperatures, a compressor refrigeration system is used in addition to the adiabatic system to provide top-up cooling.

Testing facilities

In our Test Center, located near Madrid in Spain, we can perform a variety of tests on the Air Handling Units in a state-of-the-art test chamber. This enables our clients to witness the units operating under simulated extreme conditions, providing critical information such as performance data, energy consumption and water consumption.

Test parameters

  • Function tests for simulating the safety features
  • Physical dimensions of the units
  • IT load up to 520 kW
  • Airflows up to 120,000 m3/h
  • Outdoor ambient conditions:
    • Temperature range from +10 to +50
    • Humidity range from 30% RH to 90% RH
 
Find out more on our website about: refrigeration, refrigeration system