Cold Rooms: Pressure Switches, Ball Valves, and Fan Speed Controllers

Pressure switches
While most refrigeration systems use a thermostat to regulate temperature, an alternative method is a low pressure switch, also called a low pressure control. It works using the relationship between the saturated refrigerant pressure in the evaporator and evaporating temperature. This way, the pressure switch can be set to shut off the refrigeration system when the suction pressure returning to the compressor corresponds to the correct evaporating temperature, thereby controlling the temperature of the cold room.
 A pressure switch has two main functions: protection and control. On the protective side, it limits refrigeration pressure by stopping the flow of refrigerant if pressures exceed a safe operating limit or if pressures drop too low, usually caused by a leak in the system. On the control side, controlling the pressure also controls various aspects in the cooling cycle, like compressor cycling, fan cycling, and pump-down. Basic pressure switches can either be for high or low pressure. If the refrigerant discharge pressure builds too high, the switch flips from closed to open, lowering the pressure. Similarly, if the suction pressure falls too low, the switch flips closed again, bringing the pressure back up to an acceptable level. As with thermostats, correctly setting the differential is vital in ensuring proper operation.
Ball valves
Ball valves are manually operated, shut-off valves, typically used in liquid, suction and hot gas lines. Ball valves get their name due to their internal structure: the shut off mechanism is ball-shaped. By having this shape, a simple quarter turn is all that is needed to seal the valve, cutting the flow of the refrigerant. Not only is the seal tight, but it is also very reliable, being able to make a complete seal after years of disuse. And while ball valves lack the fine control of other valve types, they are not intended for anything other than an on/off function.
 While the ball valve will remain unused in the open position during normal operation, it becomes invaluable during maintenance and repairs. By having ball valves installed in a cold room’s refrigeration system, refrigerant can be blocked off in one section or another. That means that less refrigerant will need to be recovered, saving time and money in the form of labor and materials. Ball valves are superior to other types of shut-off valves, such as right-angle and Z-pattern valves, because ball valves are able to operate without any drop in pressure. When these other types of shut-off valves are in the open position, the refrigerant is forced to change direction, both slowing it down and creating tiny eddies or vortices where the flow changed direction. Conversely, when ball valves are open, the internal opening in the ball is the same size as the surrounding pipe, ensuring that the refrigerant will flow without any impedance.
Fan speed controllers
Fan speed controls are increasingly being used in cold rooms due to their ability to reduce noise and stabilize condensing pressures under different climatic conditions. Along with those benefits, fan speed controls can often increase a cold rooms energy efficiency. By maintaining a constant low speed, fans will consume less electricity than when simply switching between running at full speed and being off.
 An additional factor to consider is the operation of the evaporator fan motors. Under normal operating conditions, the fan motors run 24/7, adding heat into the cold room and consuming energy in order to continually move air around. A more customized control option includes turning the evaporator fans off during the thermostat off-cycle and pulsing the fans for part the time to ensure the cold room air temperature is circulated over the thermostat sensor, achieving a stable cold room temperature. Depending on the application, another control option is using two speed fan motors for special areas like preparation rooms for food processing. Each of these products affect a relatively small aspect of the refrigeration cycle of a cold room, but they add up, with the end result being an energy efficient cold room suitable to your needs.  

Read More

Get the daily refrigeration briefing

One email a day. Trusted by 3,000+ RACHP professionals.

Secop's Solar Direct Drive (SDD) System Earns WHO PQS Approval – The Team Behind It
Article

Secop’s Solar Direct Drive (SDD) System Earns WHO PQS Approval – The Team Behind It

Partner's material In March 2026, Secop’s Solar Direct Drive Power Management Module was granted WHO PQS prequalification and officially listed in the WHO Catalogue of Prequalified Immunization Devices. The WHO IMD-PQS (Immunization Devices Performance, Quality and Safety programme) is the global benchmark for cold chain equipment used in immunisation. Being listed in its catalogue is

22 Jun 2026
Secop Revolutionizes Medical Cooling with Advanced ULT Condensing Units
Article

Secop Revolutionizes Medical Cooling with Advanced ULT Condensing Units

Partner's material Secop, a leading expert in advanced hermetic compressor technologies and cooling solutions, has introduced a groundbreaking advancement in ultra-low temperature (ULT) refrigeration with its new ULT Condensing Unit featuring the MS18UVULTM variable-speed drive (VSD) R290/R170 compressor. This innovation is set to significantly improve the safety, efficiency, and reliability of medical cooling, particularly for

10 Jun 2025
Event Report

Chillventa 2026 Preview: Key Technologies Ahead of the October Show

Exhibitors arriving in Nuremberg on 13 to 15 October are no longer arguing about whether to move to natural refrigerants. They are showing how fast the move can be made, and at what cost. That single change of question runs through nearly every release we have received ahead of Chillventa 2026, the largest edition of

10 Sep 2026
A Stop at the BITZER Booth at EuroShop 2026: New CO2 Units and Retrofit Performance Kits
Interview

A Stop at the BITZER Booth at EuroShop 2026: New CO2 Units and Retrofit Performance Kits

At EuroShop 2026, Sergei Mukminov, Editor-in-Chief of Refindustry.com, spoke with Jörg Wittmann, Key Accounts & Market Sector Supermarket Sales EMEA BITZER, at the BITZER booth about two practical themes for food retail refrigeration: what’s next in CO2 condensing units, and how to improve part-load performance in existing compressor installations after store retrofits such as adding

Sergei Mukminov · 13 Mar 2026
Engineering R290 Excellence: Inside Secop's Latest Compressor Innovation
Interview

Engineering R290 Excellence: Inside Secop’s Latest Compressor Innovation

By: Ilana Koegelenberg   In an exclusive interview with Refrigeration Industry, Secop's Head of Sales Europe, Massimo Gentile, provides insights into how the company's groundbreaking compressor technology addresses the increasing demand for high-efficiency hydrocarbon refrigeration solutions across an expanding range of commercial applications.   The commercial refrigeration industry continues transitioning toward more sustainable refrigerants, with

Ilana Koegelenberg · 6 May 2025
Danfoss and Bock: Shaping the Future of Refrigeration - A Conversation with Kristian Strand at Chillventa 2024
Interview

Danfoss and Bock: Shaping the Future of Refrigeration – A Conversation with Kristian Strand at Chillventa 2024

At Chillventa 2024, Sergei Mukminov, Editor-in-Chief of RefIndustry.com, interviewed Kristian Strand, President of Danfoss Commercial Compressors (President of Danfoss Climate Solutions since April 1, 2025), at the Danfoss booth. The conversation delved into Danfoss’ recent acquisition of Bock compressors, their vision for the future, and the company’s commitment to energy efficiency and sustainability in the

Sergei Mukminov · 17 Oct 2024

Most read insights

All insights →
Everything on Commercial Refrigeration: 1,315 articles, 2 case studies, 99 insights