Roller has been working on the energy optimisation of its air coolers for quite some time. In addition to the already introduction of energy-efficient EC fans installed as standard, large heat exchanger surfaces and energy-optimised pipe geometries, Roller has now addressed the issue of defrosting efficiency.
The system was optimised by combining defrosting options into an integrated defrosting concept. A supermarket retailer with more than 4000 stores across Europe is planning to further reduce its energy costs in refrigeration technology. In a calculation model, a commercial deep-freeze evaporator with a cooling capacity of approx. 3 kW achieves an average savings potential of approx. 2.5 kWh per day or 900 kWh per year. With one freezer room per branch, this means that approx. 3.6 million kWh can be saved per year. This corresponds to an annual electricity consumption of about 1000 households. The aim of the Roller defrosting concept is to make the defrosting cycles as infrequent, as short and as efficient as possible in order to reduce the frequency ideally to only one defrosting per day. The cost of the defrosting equipment is amortised after only about 1.5 years.
This energy-efficient defrosting concept is the result of various individual measures, which can only achieve its full savings potential in the interaction of all components.
The proven, aligned Roller pipe system with 12mm fin spacing is used, which provides sufficient surface area as a frost store and, combined with optimally positioned electric heating rods connected in series in aluminium jacket pipes, facilitates the defrosting process. The defrosting process is also supported by the shut-up and defrost dome, which leave the defrosting heat in the cabinet during the defrosting process and make maximum use of it. This also ensures that escaping heat from conventional defrosting processes without a defrosting concept does not have to be removed from the room by additional cooling power, which would further reduce the overall energy efficiency of the system.
This concept is rounded off by the use of the innovative, pre-installed EVD-ice control system, which consists of an electronic expansion valve and superheat controller and ensures efficient, safe operation with its precise control of the refrigerant flow and optimum charging of the evaporator.
In Roller's own laboratory, the interaction of the optional defrosting components was researched in numerous tests. It was proven that the defrosting efficiency can be increased considerably. With a well-designed system, energy savings of up to 75% can easily be achieved and the defrosting cycles can be reduced to up to one cycle per day.
With this innovation, Roller offers its customers a solution that makes a significant contribution to reducing energy costs and thus an active contribution to climate protection.