Irish food producer invests in smarter cooling solution
22 May 2024

Irish food producer invests in smarter cooling solution

Choosing the right chiller is a major financial investment and reliable cooling temperatures in food production are critical. No one knows this better than Avondale Foods, one of Ireland’s leading food manufacturers and suppliers.

An Aermec chiller is delivering energy saving benefits to Avondale Foods as part of the company’s strategy to boost efficiencies, reduce its carbon footprint and be better placed to cope with any future growth.

When faced with the prospect of replacing an aged chiller and the financial outlay required, Avondale took a pragmatic approach and saw an opportunity to incorporate the advantages of modern technologies to boost efficiencies and drive down its carbon emissions. The business was also keen to maximise its investment, by future-proofing as much as possible and design in spare capacity to be able to meet further increases in demand for its products.

Avondale worked closely with Aermec, Powertech Refrigeration and Falkonair UK, specialists in energy efficient systems and solutions to achieve the desired energy efficient HVAC-R solution.

The stringent brief required a modern chiller, which offered scope for increased capacities, delivered lower running costs, lower noise levels, an attractive ROI but also the capacity to react to changes in product loads and quickly.

Following a detailed inspection and assessment of the site’s requirements, an Aermec NRB0800Y high efficiency air-cooled chiller was selected.

Aermec’s air cooled chiller cools water down to 0⁰C and then circulates the water in a chilled water loop through a heat exchanger which provides chilled water for food processing. The unit has a nominal cooling capacity of 129.7kW.

The NRBY provides a reliable supply of cool water for the cold-water tanks within an acceptable tolerance and the heat exchanger provides cooling for the soups and coleslaws.

Although the new chiller is highly efficient, Avondale was keen to further maximise energy savings using a smart compressor control using Variable Speed Drives (VSDs). VSDs were integrated on both the refrigeration circuits, and this reduced the chiller’s energy consumption further, even when running continuously at high loads. The VSD’s enable modulation of the scroll compressors operation in Aermec’s air-cooled chiller.

The chiller’s four compressors were rated at a nominal electrical consumption of 30kW. Data acquired showed that the chiller was on standby 46% of the time, ran one or two compressors for 27% of the time and only used three of the four compressors for 6% of the time. During standby the chiller cycled in and out to maintain the required temperatures. The chiller showed a reduction in electrical consumption of 41% which was largely as a result of the VSD drives.

“Retrofitting variable speed drives helped us achieve the energy savings anticipated by Avondale thereby meeting their environmental objectives,” says David Evans, Aermec’s General Sales Manager.

The site presented a number of logistical challenges requiring a crane and mounting on custom-built steel frames. The installation and commissioning was carried out in the evening to avoid any disruption to production. All the pipework and connections were carried out in advance.

Some modifications were carried out such as a fast re-start within three minutes, reducing the risks of expensive downtime and ensuring fast delivery of chilled water at the desired temperature.

A smooth handover ensured there was no interruption to production and Avondale now benefits from a cooling solution that will continue to perform optimally, delivering efficiencies whilst reducing emissions, and offering an attractive ROI.
Related tags: chiller, HVAC, refrigeration
Share
Subscribe to the Refindustry Daily Newsletter
Trusted by 3,000+ refrigeration professionals worldwide
or sign up with
Google
LinkedIn
Facebook
No spam. Only industry-relevant news.
Unsubscribe anytime.

Related news

Trane Technologies Reports Growth in Commercial HVAC Bookings and B...
Trane Technologies reported a strong performance in its commercial HVAC segment for the fourth quarter and full year 2025, driven by high bookings and record backlog levels. The company saw continu...
09 Feb 2026
Frigoveneta acquires SAIM
Ambienta SGR announced that its platform company Frigoveneta S.p.A. has completed the acquisition of SAIM Impianti S.r.l. and SAIM Service S.r.l. (“SAIM”), a company specializing in the design, ins...
13 Feb 2026
SYCLEF enters Polish market with acquisition of PHI Group
SYCLEF has announced the integration of PHI (Polski Holding Instalacyjny), marking its first strategic operation in Central Europe. The move brings the international refrigeration and HVAC speci...
12 Feb 2026
Trane Technologies and CIT launch sustainable refrigeration trainin...
Trane Technologies has partnered with Cambridge Institute of Technology (CIT) in Bengaluru to inaugurate the Centre for Sustainable Refrigeration and Climate Control. The new facility aims to stren...
09 Feb 2026
Eurovent publishes guidance on environmental reporting for commerci...
Eurovent has released a new Recommendation on complementary Product Category Rules (cPCR) for commercial refrigeration equipment. The guidance provides a harmonised methodology for preparing Enviro...
10 Feb 2026
Nidec develops prototype liquid-cooling CDU for AI data centers und...
Nidec Corporation has announced the development of a prototype Coolant Distribution Unit (CDU) based on the Google Open Compute Project (OCP) specification for Project Deschutes. The prototype was ...
17 Dec 2025