Multi-Refrigerant Release of Secop Compressor Types R448A and R449A
04 February 2022

Multi-Refrigerant Release of Secop Compressor Types R448A and R449A

Various new refrigerant types have been developed by the chemical industry to offer alternative solutions to hydrocarbons while some high-GWP refrigerants will be phased out due to global regulations.

R448A and R449A are refrigerants which are designed to work as “drop-in” or replacement refrigerants for R404A. Secop ran analysis projects to verify that existing compressor types are compatible with these new refrigerants. As a result, the following compressors have been identified as being able to run with R404A as well as with R448A and R449A yet with slightly different operating limits:
tabl ref.png

Authority Approvals and Identification

Until further notice, Secop will not apply for authority approvals for operation with R448A and R449A of the above listed compressors. “R448A” and “R449A” notes will not be added to the type labels of the compressors. Pages which show cooling performance and adjusted operation limits for operation with R448A or R449A will be added to the compressor datasheets.

Cooling Performance and Operation Limits with Different Refrigerants

Using the new refrigerant mixtures results in a slightly different cooling performance compared to the original refrigerant. This deviation is not similar for all operation conditions, and it is not the same for all compressor types. Besides cooling performance, this affects some important temperatures inside the compressor when the new refrigerant is used. Depending on the operating conditions and compressor design, temperature changes in the motor and pumping unit happen when comparing both refrigerants on the same compressor. As a result, the operation limits of the compressors were re-defined for operation with R448A and R449A. Adjusted operation limits and new cooling performance are shown for the new refrigerants on separate pages in the compressor datasheets.

Starting Equipment and Accessories

Changes to starting equipment or other accessories are not needed. All equipment is compatible with reference and new refrigerants.

Changing the Refrigerant Type of a Cooling System – Lessons Learned

Secop has analyzed changing the refrigerant inside a commercial cooling appliance from R404A to “new” refrigerant. We have summarized the general results below:

Use as a pure drop-in

Fill in equal mass of other refrigerant R404A > R448A or R449A no other changes

New setup works with moderate results:
• discharge gas temperature is higher
• cooling performance is lower
• energy efficiency is lower
• operating pressures are higher > risk of early safety cut off

Use as drop-in + optimization of refrigerant charge amount and capillary tube

New setup works as good as with the reference refrigerant:
• discharge gas temperature is higher
• cooling performance is lower
• energy efficiency at previous level
• operating pressures at previous level > unchanged overload behavior of cooling system

Refrigerant change in appliances with need for accurate temperature regulation

Compared to R404A, a relevant temperature glide occurs with the use of R448A and R449A. This can result in lower energy efficiency and slightly lower cooling capacity even after optimization.

Recommendations

Do not use R448A and R449A with SECOP compressors for LBP operation. Temperatures inside the compressors may increase to a level where safety cut-offs occur during normal load conditions. When changing from R404A to R448A or R449A in commercial appliances, technical adaptations are needed to keep the cooling performance at the previous level and to avoid safety cut-off inside typical operation range.
Always optimize charging amount and capillary tube size for new refrigerant.
Related tags: Secop, R404A
Share
Secop GmbH
Germany, Schleswig-Holstein
secop.com
About company All company news
gold partner
Subscribe to the Refindustry Daily Newsletter
Trusted by 3,000+ refrigeration professionals worldwide
or sign up with
Google
LinkedIn
Facebook
By subscribing, you create a free Refindustry account and agree to our Terms of Service and Privacy Policy.
No spam. Only industry-relevant news.
Unsubscribe anytime.

Related news

Secop BD Nano Compressor Powers Vitrifrigo RV Refrigerator in Effic...
A recent case study highlights the performance of the Vitrifrigo C51i HP refrigerator, equipped with Secop’s BD Nano compressor, in addressing key off-grid refrigeration challenges in recreational ...
03 Feb 2026
Deutsche Messe uses ebm-papst NEXAIRA for retrofit
Deutsche Messe AG has connected technical installations at its Pavilion 36 to ebm-papst’s NEXAIRA digital ecosystem as part of an energy-efficiency retrofit ahead of Hannover Messe 2026 in Germ...
08 Apr 2026
Alfa Laval reports record annual sales and earnings in 2025
Sweden-based Alfa Laval has reported its financial results for the fourth quarter and full year 2025, highlighting record levels of net sales and adjusted EBITA, driven by strong performance across...
10 Feb 2026
CAREL reports 2025 growth in HVAC and refrigeration
CAREL Industries said its board approved consolidated results for the year ended 31 December 2025, with revenue up 8.7% year on year to €629.0 million [about $686 million], or 10.6% at constant exc...
11 Mar 2026
Carrier Opens €12m Montluel HVAC and Data Centre Test Lab
Carrier announced a €12 million testing facility at its European Centre of Excellence in Montluel, France, expanding research and development capacity for cooling and heating technologies used in d...
09 Apr 2026
Secop introduces KL-CNQX tropical compressors for propane cabinet s...
Secop has launched new tropical KL-Series compressors, including the KL-CNQX, targeting the next generation of light commercial cabinets using environmentally friendly refrigerant propane. The comp...
02 Mar 2026