Panasonic Cools Data Centre with Aircon in Belfast, Northern Ireland

One of the main challenges for data centres is coping with cooling and humidity control demands within the building because of the enormous heat gains generated by the large volume of computers and lighting systems – often in operation 24 hours a day, seven days a week. In the case of Concentrix Customer Engagement Centre in Belfast, there was also the added complication of the number of employees on site approaching close to 1500 people.

<img class="alignnone size-medium wp-image-13200" src="https://refindustry.com/wp-content/uploads/2018/06/panasonic-data-center-500x333.jpg" alt="" width="500" height="333" />

The installation at Concentrix was a very complex and challenging project due to the building’s design and lack of available electrical supply to the site. In addition to the nature of Concentrix’s business, which requires a significant power load for the operations of the building including lighting, computers and servers, the property also needed to provide comfortable conditions for the 1500 employees on site.

The team at Aircon’s contracts department, headed up by Manager, Stephen McGarry, worked closely with consultants Beattie Flannigan and mechanical contractors, Harvey Group, to deliver the best possible solution that site conditions would allow. Ian McFerran, Aircon’s Managing Director explains, “Quality underpins our entire delivery model, with professionalism and attention to detail being the primary focus. Coupled with competitive and cost-effective pricing, the overall package we deliver sets us apart from other market players

Due to the design of the building which features low ceiling heights on each floor, the team devised a solution based on a larger quantity of indoor units operating at lower capacities. Not only that, the Panasonic DX gas-fired system provides close to 1.2MW of cooling, using between 20kW and 25kW of electrical input, thus efficiently providing optimum cooling for the building whilst only drawing a minimal load from the buildings electrical power supply.

The equipment specified included the following

• 13 Panasonic GHP gas heat pump 3-pipe outdoor units
• 5 Panasonic GHP 2-pipe VRF outdoor units to service AHU DX Systems
• 155 Panasonic VRF cassette indoor units to serve all call centre and meeting room areas
• 19 Panasonic Split Hi Wall systems to serve various small UPS and comms rooms
• Panasonic centralised and full Modbus BMS control
• Panasonic Air Off Control employed in all call centre area’s to provide a very high sensible heat ratio, 90%+
• All indoor units were sized to meet duties at medium to low fan speeds

This project benefits from a sophisticated solution offering high performance, is cost-effective, energy efficient and 100% reliable.
Related tags: heat pump
Share
Subscribe to the Refindustry Daily Newsletter
Trusted by 3,000+ refrigeration professionals worldwide
or sign up with
Google
LinkedIn
Facebook
By subscribing, you create a free Refindustry account and agree to our Terms of Service and Privacy Policy.
No spam. Only industry-relevant news.
Unsubscribe anytime.

Related news

Danfoss tests Triple Aqua CO2 heat pump in Denmark
Danfoss has tested the Sinop Triple Aqua CO2 heating and cooling system at its Application Development Center in Nordborg, Denmark, under calibrated heat pump test conditions. The report states tha...
27 Mar 2026
Panasonic Holds MCE 2026 Press Conference on Europe's Energy Transi...
Panasonic Heating & Cooling Solutions held a press conference at Mostra Convegno Expocomfort 2026 in Milan on 25 March, presenting its HVAC&R strategy for Europe and introducing new pro...
26 Mar 2026
Daikin wins FT fDi award for Poland heat pump plant investment
Daikin has received the Investment Impact Award from fDi Intelligence, a division of The Financial Times, for its EUR 300 million [about USD 327 million] investment in a residential heat pump p...
29 Mar 2026
Panasonic establishes HVAC & CC company
Panasonic HVAC & CC Co., Ltd. was established on April 1, 2026, as Panasonic Group moved to a new group structure. Eiichi Katayama was appointed Representative Director, Member of the Board, Pr...
today
ATMOsphere publishes clean cooling report for data centers
The latest ATMOsphere report highlights a growing opportunity for natural refrigerant-based cooling systems in the data center sector, driven by rapid global expansion of high-performance computing...
03 Feb 2026
Eurovent Certita Certification reports 88/100 Gender Equality Index...
Eurovent Certita Certification has published its Gender Equality Index results for the year 2025, reporting an overall score of 88 out of 100. Since January 2019, companies with at least 50 employe...
26 Mar 2026