Panasonic Cools Data Centre with Aircon in Belfast, Northern Ireland

One of the main challenges for data centres is coping with cooling and humidity control demands within the building because of the enormous heat gains generated by the large volume of computers and lighting systems – often in operation 24 hours a day, seven days a week. In the case of Concentrix Customer Engagement Centre in Belfast, there was also the added complication of the number of employees on site approaching close to 1500 people.

<img class="alignnone size-medium wp-image-13200" src="https://refindustry.com/wp-content/uploads/2018/06/panasonic-data-center-500x333.jpg" alt="" width="500" height="333" />

The installation at Concentrix was a very complex and challenging project due to the building’s design and lack of available electrical supply to the site. In addition to the nature of Concentrix’s business, which requires a significant power load for the operations of the building including lighting, computers and servers, the property also needed to provide comfortable conditions for the 1500 employees on site.

The team at Aircon’s contracts department, headed up by Manager, Stephen McGarry, worked closely with consultants Beattie Flannigan and mechanical contractors, Harvey Group, to deliver the best possible solution that site conditions would allow. Ian McFerran, Aircon’s Managing Director explains, “Quality underpins our entire delivery model, with professionalism and attention to detail being the primary focus. Coupled with competitive and cost-effective pricing, the overall package we deliver sets us apart from other market players

Due to the design of the building which features low ceiling heights on each floor, the team devised a solution based on a larger quantity of indoor units operating at lower capacities. Not only that, the Panasonic DX gas-fired system provides close to 1.2MW of cooling, using between 20kW and 25kW of electrical input, thus efficiently providing optimum cooling for the building whilst only drawing a minimal load from the buildings electrical power supply.

The equipment specified included the following

• 13 Panasonic GHP gas heat pump 3-pipe outdoor units
• 5 Panasonic GHP 2-pipe VRF outdoor units to service AHU DX Systems
• 155 Panasonic VRF cassette indoor units to serve all call centre and meeting room areas
• 19 Panasonic Split Hi Wall systems to serve various small UPS and comms rooms
• Panasonic centralised and full Modbus BMS control
• Panasonic Air Off Control employed in all call centre area’s to provide a very high sensible heat ratio, 90%+
• All indoor units were sized to meet duties at medium to low fan speeds

This project benefits from a sophisticated solution offering high performance, is cost-effective, energy efficient and 100% reliable.
Related tags: heat pump
Share

Related news

Daikin Europe reports €5.03B FY2024 turnover with growth in commerc...
Daikin Europe N.V. has reported an annual turnover of €5.03 billion for fiscal year 2024, ending March 31, 2025. This result reflects a slight increase over the previous year and contributes to...
13 May 2025
Aira Names Peter Prem CEO and Anthony Loizeau Deputy CEO to Acceler...
Leadership shift aims to strengthen operational execution and market expansion. Aira has appointed Peter Prem as Group CEO and Anthony Loizeau as Group Deputy CEO of Market Operations, e...
07 May 2025
Mitsubishi Electric Heat Pumps Power Weber State University’s HVAC ...
Hybrid VRF systems support energy goals and student training at Utah campus. Weber State University in Ogden, Utah, is deploying Mitsubishi Electric Hybrid VRF heat pump systems
10 May 2025
Viessmann Launches Vitocal Heat Pumps for Residential and Light Com...
Viessmann US has introduced two new lines of air-to-air heat pumps—Vitocal 100-S and Vitocal 200-S—designed to enhance energy efficiency and comfort in residential and light commercial settin...
11 May 2025
BITZER UK Hosts WiRACHP Strategic Planning Meeting at Milton Keynes HQ
BITZER UK hosted the Institute of Refrigeration’s Women in RACHP (WiRACHP) Network for its first in-person meeting of 2025 at the company’s Milton Keynes headquarters. The all-day event gathered ei...
12 May 2025
AHRI: U.S. AC and Heat Pump Shipments Down 2.4% in March
The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) reported that U.S. shipments of central air conditioners and air-source heat pumps totaled 818,761 units in March 2025, marking a 2...
yesterday