BAC introducing the new Polairis Model PLF2

The PolairisTM model PLF2 closed circuit cooling tower brings reliability to the next level.
This innovative unit, that incorporates highly efficient radial fans with EC motors as well as the DiamondClear Design, offers you a year-round, trouble-free and energy efficient operation in combination with a minimal need for maintenance.

Key benefits

  • Extremely reliable
  • Superb hygiene
  • Minimal maintenance and easy inspection

Extremely reliable

  • The Polairis closed circuit cooling tower's design incorporates all experience BAC acquired over the last decades with thousands of VXI units installed globally since 1978.
  • Fan drive systems are located inside the unit, in the dry air, preventing condensation and eliminating corrosion issues and premature failures.
  • Direct driven fans eliminate potential mechanical failures.
  • Multiple, individually driven fans guarantee redundancy.
  • The thermal performance of Polairis closed circuit cooling towers is tested and certified by Eurovent.
  • Baltibond hybrid coating for maximum equipment life, with corrosion resistance equivalent to SST 304L.
  • Dry operation possible.

Superb hygiene

  • The DiamondClear Design* offers a continuous self-cleaning operation. During standstill the sloping surfaces fully drain, avoiding stagnant water and the risk of sedimenation of impurities.
  • A completely encased collection basin eliminates any sunlight ingress, preventing biological growth.
  • Baltibond hybrid coating for a smooth surface finish that reduces biofilm development.
  • The floor is fully sloped towards the drain - also in the dry section - for easy cleaning.
  • Water treatment system connections are provided as standard.

Minimal maintenance and easy to inspect

  • Direct driven fans require no maintenance at all.
  • The DiamondClear Design* offers a continuous self-cleaning operation. The need for maintenance is minimized by using fully sloping surfaces, a constant impact of falling spray water and high water velocities.
  • The double blank-off wall guides the spray water into the collection basin, which makes it subject to higher turbulences. This turbulence reduces the risk for sediments to settle down and reduces the need for collection basin cleaning.
  • Two large access doors are included in the default unit construction for easy access to all critical components. 
  • Unmatched accessibility to the basin, drives and fans in the dry section, via the mansized access door at ground level.
  • Water distribution system is easily accessible from outside.
  • Baltibond hybrid coating for a smooth surface finish that facilitates internal cleaning.

Flexible to install

  • Fans are prewired to a terminal box to avoid time-consuming on-site wiring. Integrated electronics of EC motors eliminate the need for external VFD's, electronic filters and shielded cables.
  • Installation costs are reduced since units are shipped in 2 factory-built sections with a rigid base frame that guarantees squareness for easy on-site assembly. Additionaly, single lifts are possible. 
  • Single side air intake allows for installation in confined spaces and next to solid walls.
  • Pressure capability of fans allows indoor installation with ductwork.
  • Silent radial fans reduce the need for installation of sound attenuation.

Energy efficient

  • EC motors have superior efficiency that exceeds the IE4 requirements.
  • Integrated electronics of EC motors allow for variable speed control at a significantly reduced power consumption compared to AC motors with VFD.
  • Optimized design with EC Fan Systems in combination with DiamondClear Design results in a uniform air distribution over the entire footprint of the coil, for year-round optimal certified thermal performance. 

Low sound

  • Silent radial fans are standard.
  • Single side air inlet allows directing the quiet unit rear towards noise sensitive areas.
  • Sound attenuation is available for the most stringent sound requirements.

* patent pending

Related tags: Fans
Share

Related news

Hillphoenix introduces AdvansorUltra CO₂ booster system for industr...
Hillphoenix has launched AdvansorUltra, an industrial CO₂ booster refrigeration system designed for high efficiency, serviceability, and environmental performance in industrial applications. ...
01 Dec 2025
BAC launches upgraded immersion cooling tanks for high-density data...
Baltimore Aircoil Company, Inc. (BAC) has introduced an enhanced immersion cooling tank for high-performance data centers, featuring its proprietary CorTex technology. The new solution is designed ...
13 Oct 2025
Modine adds stainless steel TurboChill DCS chiller for liquid-coole...
Modine has introduced a stainless steel variant of its Airedale by Modine TurboChill DCS chiller, designed to meet the demands of direct liquid cooling (DLC) in high-density data...
19 Nov 2025
Hillphoenix highlights CO₂ refrigeration technologies for energy-ef...
Hillphoenix, a Dover company, is promoting a suite of CO₂ refrigeration technologies designed to improve energy efficiency and support sustainability in retail applications. The company is targetin...
25 Nov 2025
BAC earns Intel certification for immersion cooling tank with Xeon ...
BAC (Baltimore Aircoil Company Inc.) has announced that its immersion cooling tank is now certified under the Intel Data Center Certified Solution for Immersion Cooling program, covering fourth and...
09 Dec 2025
Copeland introduces CO2 scroll compressor with dynamic vapor injection
Copeland has launched a transcritical CO2 scroll compressor with dynamic vapor injection (DVI) technology in North America. The new solution is designed for distributed CO2 refrigeration syst...
09 Dec 2025