Carrier Adds Heat Recovery and Free Cooling Options  Extending R-32 Scroll Chiller Energy SavingsCarrier Adds Heat Recovery and Free Cooling Options  Extending R-32 Scroll Chiller Energy Savings
14 June 2022

Carrier Adds Heat Recovery and Free Cooling Options Extending R-32 Scroll Chiller Energy Savings

Carrier has introduced high-performance heat recovery and free cooling options to its AquaSnap 30RBP air-cooled scroll chiller range on lower global warming potential (GWP) R-32 refrigerant, providing even greater energy savings and further reducing operating costs for end users. 

Carrier was the first European manufacturer to introduce a fully optimised scroll chiller range on R-32. AquaSnap units also have an outstanding seasonal energy performance ratio (SEER) for cooling of up to 6.62, reducing indirect greenhouse gas emissions resulting from energy use. The latest heat recovery and free cooling options extend energy savings, further reducing greenhouse gas emissions over the lifetime of the equipment.

The heat recovery system enables chillers to produce domestic hot water up to 80deg C, while continuing to provide cooling, useful for applications such as hotels, hospitals and industrial processes requiring hot water. The free cooling option makes use of favourable ambient and load conditions, harnessing free cooling from the environment to augment or replace mechanical cooling via the chiller's compressors, reducing energy consumption and running costs.

Two versions of free cooling are available. Partial free cooling is designed for applications with a variable primary cooling load, such as offices and healthcare, which may also have a constant residual cooling need. Examples include computer suites or scanner facilities. The total free cooling option is designed for applications with a constant cooling need throughout the year, such as industrial processes and data centres.

Carrier's hydronic-based free-cooling system automatically activates when the outdoor air temperature drops 1 degree C below the chiller's return water temperature, harnessing the full free cooling opportunity and maximising energy savings. For example in Berlin, the hydronic free cooling potential is 50 to 95% of annual chiller run-time, depending on the application. In more northern locations, the potential free cooling opportunity is even greater. 

If free cooling is not sufficient to meet requirements, a mixed mode – using both free cooling and mechanical cooling – is automatically activated, ensuring the cooling needs of mission critical applications are always met.
Related tags: chiller, chillers, Carrier
Share
Subscribe to the Refindustry Daily Newsletter
Trusted by 3,000+ refrigeration professionals worldwide
or sign up with
Google
LinkedIn
Facebook
No spam. Only industry-relevant news.
Unsubscribe anytime.

Related news

Carrier introduces AquaEdge 30CF chiller for data center cooling in...
Carrier has introduced the AquaEdge 30CF air-cooled centrifugal chiller, targeting data center operators seeking continuous cooling performance and protection of uptime under real-world operati...
02 Mar 2026
Panasonic launches CDUs and free-cooling chillers for AI data cente...
Panasonic Corporation announced that its Heating & Ventilation A/C Company has started accepting orders in Europe from March 4, 2026, for two Coolant Distribution Unit (CDU) models for generati...
05 Mar 2026
Airedale by Modine launches hybrid chiller to meet evolving AI data...
Airedale by Modine has introduced the TurboChill 3+MW, a new air-cooled chiller designed to support next-generation, GPU-powered data centers. The launch reinforces the company's position in provid...
26 Jan 2026
Trane launches R290 air-to-water heat pumps for EMEA and ANZ
Trane (a brand of Trane Technologies) has launched two air-to-water heat pumps using R290 refrigerant: FLEX N HP and ARIES N HP. The company said the new units expand its R290 portfolio for custome...
26 Feb 2026
Alfa Laval launches FreeWaterLoop system for data center cooling
Alfa Laval introduced FreeWaterLoop, an external cooling system for the data center facility loop designed to improve efficiency and support high-density computing. According to Alfa Laval, the sys...
06 Mar 2026
Carrier launches new Coolant Distribution Unit for UK data centres
Carrier has introduced a new Coolant Distribution Unit (CDU) designed to help UK data centres meet growing cooling demands while improving energy performance, system uptime and space utilisation. T...
23 Jan 2026