An industry first: Newark Refrigerated Warehouse plans propane refrigeration system for cold storage

Gerard von Dohlen, president of Newark Refrigerated Warehouse, Newark, N.J., plans to install what may be the first cold-storage refrigeration system to employ propane as its primary refrigerant.

Von Dohlen is applying to the U.S. Environmental Protection Agency (EPA) for permission to use propane for refrigeration under the EPA’s Significant New Alternatives Policy (SNAP) program.

The system, which he would like to install 12-24 months from now, will serve his two existing buildings and an additional building that will begin construction when the new refrigeration system start operation, he said.

Von Dohlen originally planned to replace the R22 currently used at his facility with low-charge ammonia systems. However, that idea fell through after the state of New Jersey abandoned a plan to relax its stringent requirements for ammonia operations. He then considered using R32 as a primary refrigerant, but decided on propane because of impending regulatory pressures on HFCs.

“The EPA made it clear again that it intends to phase out f-gases at least for refrigeration by 2030 at a meeting with the IARW,” von Dohlen said.

If approved, the propane system will contain 1,100 pounds of propane, which will be confined to a small one-story engine room attached to one of his two cold-storage buildings. Von Dohlen’s original building has 12 freezer rooms and four medium temperature rooms, with a total capacity of 250 TR; his second building has one freezer room with a 300 TR capacity.

To ensure safe operation with a flammable refrigerant, the engine room will be IIAR-2 compliant with fully automated controls, and all electrical panels will be located outside the room. “We are eliminating any potential source of ignition,” said von Dohlen.

The propane will be used to cool a calcium chloride brine solution, which will serve as a secondary refrigerant; the brine, in turn will be pumped into a Kathabar conditioner where it will cool air from the refrigerated spaces; the cool air will then be blown back into the refrigerated spaces. The brine will also serve as a desiccant and disinfectant for the refrigerated air.

Refcatalog

 

Source: www.hydrocarbons21.com

Get the daily refrigeration briefing

One email a day. Trusted by 3,000+ RACHP professionals.

More on Cold Chain

All on Cold Chain →

Insights

Secop's Solar Direct Drive (SDD) System Earns WHO PQS Approval – The Team Behind It
Article

Secop’s Solar Direct Drive (SDD) System Earns WHO PQS Approval – The Team Behind It

Partner's material In March 2026, Secop’s Solar Direct Drive Power Management Module was granted WHO PQS prequalification and officially listed in the WHO Catalogue of Prequalified Immunization Devices. The WHO IMD-PQS (Immunization Devices Performance, Quality and Safety programme) is the global benchmark for cold chain equipment used in immunisation. Being listed in its catalogue is

22 Jun 2026
Case Study - Effect of Louvers or diffusers on air flow distribution and cooling time on a meat log during Chill cycle
Tech Guide

Case Study – Effect of Louvers or diffusers on air flow distribution and cooling time on a meat log during Chill cycle

By Kushal Aurangabadkar An experimental analysis was conducted on a cooler space measuring 3.66 m × 6.096 m (12.0 ft × 20.0 ft), equipped with an ammonia refrigeration coil, five 30 cm (12 in.) fans, and five diffusers. The study measured airflow patterns, cooling rates, and heat transfer efficiency in meat storage by testing two configurations:

Kushal Aurangabadkar · 21 Jan 2026
Total Cost of Ownership (TCO) for Modular Refrigeration Systems in Life Sciences Distribution Centers
Tech Guide

Total Cost of Ownership (TCO) for Modular Refrigeration Systems in Life Sciences Distribution Centers

by Ramez Naguib, P.E. Introduction Life sciences distribution centers are under immense pressure to deliver consistent temperature control, comply with increasingly stringent regulations, and optimize operational efficiency. Traditional built-up refrigeration systems often prove cumbersome, costly, and slow to implement. In contrast, modular, factory-assembled refrigeration systems have emerged as a compelling alternative. Drawing on lessons from